Back to Study Hub
Regulated Power Supply• 15 min read

Regulated Power Supply: Rectifiers, Filters and Voltage Regulators

A complete Wireless PSI study guide to the regulated power supply — the block diagram, rectifier types with a comparison table, filters, voltage regulators (Zener, series, shunt, IC 78xx/79xx, SMPS), performance parameters, the full formula sheet, and exam shortcuts.

By MCQ Arena TeamUpdated June 22, 2026

Every radio set, base station, and handheld device on a police wireless grid runs on a clean, constant DC rail — and producing that from messy mains AC is the job of the Regulated Power Supply (RPS). It is a high-value module in the Wireless PSI syllabus because the questions are predictable: rectifier properties, ripple, the 78xx/79xx series, and short numericals on ripple factor, efficiency, and the Zener series resistor.

An RPS maintains a constant DC output despite both input AC variation (line regulation) and load current changes (load regulation). This guide walks the full signal chain and ends with the formula sheet you must memorise.

1. The block diagram

Always picture the RPS as four stages in series — drawing this block diagram is the fastest way to reason through both theory and numerical questions:

AC Mains → Transformer → Rectifier → Filter → Voltage Regulator → Regulated DC

The four stages of every linear regulated power supply

  • Transformer — steps the mains voltage down to the required level (a step-down transformer); key parameter is the turns ratio.
  • Rectifier — converts AC into pulsating DC.
  • Filter — smooths the pulsating DC by reducing the AC ripple.
  • Voltage regulator — holds the final DC output constant against line and load changes.

2. Rectifiers

A rectifier converts AC into pulsating DC. There are three types, and the comparison table below answers most rectifier MCQs directly — memorise it.

RectifierDiodesOutput frequencyPIVRipple factor (γ)V_dc
Half-wave1f (= input)V_m1.21V_m / π
Full-wave (centre-tapped)22f2·V_m0.4822·V_m / π
Bridge42fV_m0.4822·V_m / π

The bridge rectifier is the most widely used: it needs no centre-tapped transformer, gives high efficiency and low ripple, and its PIV is only Vm (versus 2·Vm for the centre-tapped full-wave).

3. Filters

A filter reduces the AC ripple from the rectifier to produce smoother DC. The key parameter is the ripple factor — lower is better.

  • Capacitor (shunt) filter — most common; bypasses AC components to ground while the capacitor holds up the DC.
  • Inductor (series) filter — opposes sudden changes in current; better for high-current loads.
  • LC filter — inductor + capacitor; gives better ripple reduction than either alone.
  • RC filter — resistor + capacitor; used in low-current applications and as a pre-filter.

4. Voltage regulators

The regulator is what makes the supply "regulated." The main types, from simplest to most efficient:

  • Zener diode regulator — simplest; a Zener in reverse breakdown holds a stable reference voltage. Good for low power.
  • Transistor series regulator (emitter follower) — a pass transistor in series with the load; output follows the reference voltage; good load regulation.
  • Transistor shunt regulator — transistor in parallel with the load; less efficient than the series type.
  • IC regulators — compact, reliable, easy to use (see 78xx/79xx below).
  • SMPS — high-efficiency switching regulators (see below).

IC regulators: 78xx and 79xx

  • 78xx series — positive fixed voltage regulators (e.g. 7805 = +5 V, 7812 = +12 V).
  • 79xx series — negative fixed voltage regulators (e.g. 7905 = −5 V, 7912 = −12 V).
  • Adjustable regulators — output set by external resistors (e.g. LM317 positive, LM337 negative).
  • Dropout voltage — the minimum input-to-output difference a linear regulator needs to keep regulating. An LDO (Low Dropout) regulator works with a very small difference.

Switching Mode Power Supply (SMPS)

An SMPS rapidly switches the DC input on and off at high frequency, then rectifies and filters the result back into regulated DC. It is far more efficient than a linear regulator, at the cost of complexity and possible EMI.

SMPS (switching)Linear regulator
EfficiencyHigh (small heat loss)Low (dissipates excess as heat)
CircuitComplexSimple
Noise / EMIPossible EMILow noise, clean output
Size / weightSmaller, lighterBulkier (heat sink)

SMPS topologies: Buck (step-down), Boost (step-up), and Buck-Boost (either, with inverted polarity).

5. Zener diode as a regulator

  • Operates in the reverse breakdown region, holding a nearly constant Zener voltage (VZ).
  • Works correctly only when its current stays between IZ(min) and IZ(max).
  • A series resistor RS limits the current and protects the diode — calculating it is a classic numerical (formula below).

6. Performance parameters

  • Line regulation — % change in output for a change in input voltage. Lower is better.
  • Load regulation — % change in output from no-load to full-load current. Lower is better.
  • Ripple factor — RMS AC ripple ÷ DC output; measures filter quality.
  • Output impedance — internal resistance seen at the output; lower is better.
  • Efficiency — output power ÷ input power.
  • Transient response — how quickly the output recovers after a sudden load or input change.

7. Formula sheet

Rectifier output

Half-wave: Vdc = Vm/π | Full-wave / Bridge: Vdc = 2·Vm/π

DC (average) output voltage

Half-wave: Vrms = Vm/2 | Full-wave / Bridge: Vrms = Vm/√2

RMS output voltage

Half-wave: γ = 1.21 | Full-wave / Bridge: γ = 0.482

Ripple factor (lower is better)

Capacitor filter ripple (peak-to-peak)

Half-wave: Vr = Idc/(f·C) | Full-wave: Vr = Idc/(2·f·C)

I_dc = DC load current, f = input frequency, C = filter capacitance

Zener regulator

RS = (Vin − VZ) / (IZ + IL)

Series resistor; choose R_S to keep I_Z within limits across the load range

PZ = VZ × IZ

Zener power dissipation

Performance

Line reg = (ΔVout / Vout) × 100% | Load reg = ((VNL − VFL) / VFL) × 100%

Lower percentages mean better regulation

η = (Pout / Pin) × 100% | Ripple factor = Vr(rms) / Vdc

Efficiency and ripple factor

8. Exam shortcuts

  • Rectifier frequency & PIV: half-wave → output freq = input freq, PIV = Vm; full-wave centre-tapped → 2f, PIV = 2·Vm; bridge → 2f, PIV = Vm.
  • 78 = positive, 79 = negative. Easy to spot in MCQs (7805 = +5 V, 7905 = −5 V).
  • Lower % = better regulation for both line and load regulation.
  • Watch your units — mV↔V and mA↔A conversions cause most numerical mistakes.
  • GPRB context: police vehicles are typically 12 V systems and handheld devices commonly 5 V — expect application questions framed this way.
  • GaN and SiC power devices — wide-bandgap semiconductors enabling higher switching frequencies, smaller size, and better efficiency in compact, rugged field equipment.
  • Digital power management — microcontrollers/DSPs give precise voltage control, real-time monitoring, and predictive maintenance.
  • Power over Ethernet (PoE) — delivers data and power on one cable for IP cameras and wireless access points, removing separate power wiring.
  • Improved EMI/EMC — quieter switching designs protect sensitive wireless and surveillance equipment from interference.
  • Energy harvesting — solar/kinetic integration for self-sustaining remote sensors and off-grid relays.
Key Takeaways
  • RPS chain: Transformer → Rectifier → Filter → Regulator → constant DC.
  • Bridge rectifier: 4 diodes, 2f output, PIV = V_m, ripple factor 0.482 — the most used.
  • Centre-tapped full-wave PIV = 2·V_m; half-wave ripple factor 1.21 (poor).
  • 78xx = positive fixed regulators; 79xx = negative; LM317/337 = adjustable.
  • SMPS = high efficiency but EMI-prone; linear = simple, clean, but wastes heat.
  • Zener regulator: reverse breakdown, R_S = (V_in − V_Z)/(I_Z + I_L); lower line/load % = better.

Test yourself

The rectifier comparison table (frequency, PIV, ripple factor) and the Zener series-resistor calculation are the two highest-yield areas. Drill them with timed MCQs on MCQ Arena, watching your mV↔V and mA↔A conversions, until the 78xx/79xx distinction and the rectifier numbers are instant recall.

MA

MCQ Arena Team

Subject reviewers & exam mentors

This guide is written and fact-checked by the MCQ Arena editorial team — engineering graduates and competitive-exam mentors who build the question banks used on the platform. Every concept, formula and MCQ is cross-checked against standard textbooks and the latest Wireless PSI / GPSC exam pattern. Spotted an error or have a correction? Tell us — we update articles as syllabi and feedback come in.

Last reviewed and updated on June 22, 2026.

Put it into practice

Reading strategy is one thing — building it into instinct takes timed reps. Practise with daily timed mock tests on MCQ Arena.

Start practising free

Keep reading